● A LITTLE OCEAN. A WORLD TO UNDERSTAND.
Reef guide

Dosing: consumption first, product second

Do not turn an isolated deviation into an automatic dose.

Separate consumption and correction

Maintenance dosing replaces demonstrated consumption; correction dosing changes a confirmed value. These are different questions. First check salinity, test method and repeatability. Consider water changes, feeding, growth and products already adding the same component.

Required information

You need a reasonable net-volume estimate, exact product, manufacturer-stated concentration or effect, and compatible units. Keep label, batch and preparation date for dilutions. If information is missing, the tool must not invent a dose. Do not extrapolate between similar-looking products.

Measure consumption

Use comparable measurements during a stable period and log all inputs. A difference smaller than kit uncertainty is not precise consumption. Establish a trend before changing routine and verify prepared concentration. Geometric volume without displacement corrections is not certified net water volume.

Apply with control

Follow the actual product instructions and limits. Split adjustments when appropriate and retest before continuing. Avoid direct tissue contact and unauthorized component mixing. Verify pump output with a measured container; a schedule does not prove delivery.

What this platform does not do

ReefFrag does not control dosing pumps or calculate generic supplements of unknown concentration. An ICP report does not justify adding every apparently low element or establish bioavailability. Confirm sampling, contamination and context before acting on an unexpected result.

An insufficient-data example

A user observes an alkalinity decline but knows only a nominal 200 L tank rating and has an unreadable buffer label. Millilitres cannot be calculated. Establish actual water estimate, product, concentration and test validity. The application should identify missing data and save the observation without a recipe. Later calculations must follow that actual product rather than another manufacturer’s generic table.

Distinguish trend from noise

Two different tests do not always establish daily consumption. Log intervals, conditions and additions and repeat consistently. Water changes or salinity shifts can alter comparison. Retain kit resolution and stated uncertainty; subtraction cannot create input precision. A graph helps reveal trends but cannot turn poorly repeatable readings into a safe instruction for automatic dose increases.

After changing a routine

Record target, actual delivery, concentration, location and time. Check for overlooked additional sources of the same component. Observe and remeasure before another adjustment; stop and review instructions for precipitation or unexpected reactions. Keep products labelled and secured. AI can organize explanations and questions but cannot replace verified product data or invent an unmeasured concentration.

Sources and review scope

Original writing assisted by AI. No professional review claimed. Check the specific instructions for your instruments, products and livestock.

Editorial status: AI-assisted documentary check; no human review claimed · 2026-11-12